| # | Date Created | Employee | Work Type | Task | Duration (Hours) | Action |
|---|---|---|---|---|---|---|
| 1 | 2025-11-07 18:49 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | 1. DL3 10 mtr OBD cables continuity checked and took trail on vehicle level. |
2.00 | |
| 2 | 2025-11-07 18:44 | Pranav Chandrakant Jagajampi | VAT Database | 1. Services verified from FRONT_ZONE.2. All services are working fine |
9.00 | |
| 3 | 2025-11-03 20:57 | Pranav Chandrakant Jagajampi | Client (External) Meetings | 1. Gate pass was blocked in MAHINDRA2. Compliance-related activity done in MAHINDRA |
9.00 | |
| 4 | 2025-11-03 20:56 | Pranav Chandrakant Jagajampi | VAT Database | 1. POTG disabling for W610 project in final line calibration option mode.2. Took a trails on vehicle level. Working fine |
9.00 | |
| 5 | 2025-10-27 18:30 | Pranav Chandrakant Jagajampi | VAT Database | New service addition in HPC_C |
3.00 | |
| 6 | 2025-10-15 13:02 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | 1. All 11 DL3 are deployed in the S block2. In 6 DL3 scanner drivers are installed3. In all 11 DL3 firmware checked |
9.00 | |
| 7 | 2025-10-14 19:37 | Pranav Chandrakant Jagajampi | VAT Database | New model code added in semi-active suspension for BEV.Calibration: MAHINDRA_5.6.41.96.24 New services added in ITM and MID_ZONE for W616. Calibration: MAHINDRA_5.7.1.94.DL3 checked. All trails done on vehicle level |
9.00 | |
| 8 | 2025-10-14 19:36 | Pranav Chandrakant Jagajampi | Client (External) Meetings | Regarding the new project discussed with the MAHINDRA team with Manesh sir |
4.00 | |
| 9 | 2025-10-14 19:35 | Pranav Chandrakant Jagajampi | VAT Database | , POWER WINDOWS calibration is disabled from the FINAL_FLASHING_API station.Took trails one vehicle level working fine. |
5.00 | |
| 10 | 2025-10-06 17:42 | Pranav Chandrakant Jagajampi | VAT Database | 1. All services added in VAT database HPC_C_MCM_UDS over CANFD_0750_0758 HPC_C_MCM_FEATURE_CODE DID - 0DFF, Length - 91, Type - Write HPC_C_MCM_RSA DID - 0E04, Length - 15, Type - Write HPC_C_MCM_E_CALL DID - 0E02, Length - 15, Type - Write HPC_C_MCM_SOS DID - 0E03, Length - 15, Type - Write HPC_C_MCM_OVERSPEED_ALERT DID - 0DED, Length - 3, Type - Write HPC_C_MCM_VALET_MODE DID - 0E00, Length - 4, Type - Write HPC_C_MCM_FUEL_LOG_CONFIG DID - 0DEC, Length - 3, Type - Write HPC_C_MCM_SMART_PERSONALIZATION DID - 0E06, Length - 2, Type - Write HPC_C_MCM_ASK_MAHINDRA DID - 0764, Length - 15, Type - Write MCM_UDS over CAN_07C1_07C9 MCM_FEATURE_CODE DID - 0DFF, Length - 91, Type - Write MCM_BOOTSTRAP_TRIGGER DID - FD04, Length - 1, Type - Write MCM_PROJECT_CODE DID - 0E13, Length - 8, Type - Write MCM_BOOTSTRAP_STATUS DID - FD03, Length - 1, Type - Read MCM_CLOUD_ENDPOINT_CONFIGURATION DID - 23C7, Length - 1, Type - Write 2. New model code added of Z1 in option type. |
6.00 | |
| 11 | 2025-10-06 17:40 | Pranav Chandrakant Jagajampi | VAT Database | Final line TPMS services addition. Power window learning routine modification.Testing and validation done on vehicle level |
9.00 | |
| 12 | 2025-10-01 21:40 | Pranav Chandrakant Jagajampi | VAT Database | 1. New services added in all modules of W616 2. New services are verified. |
5.00 | |
| 13 | 2025-09-26 18:38 | Pranav Chandrakant Jagajampi | Client (External) Meetings | Future roadmap discussed with mahindra team |
2.00 | |
| 14 | 2025-09-26 18:37 | Pranav Chandrakant Jagajampi | VAT Database | 1. HPC_V service added2. CRM enabled in Final_flashing_api3. CRM new model code added in broadcast decode4. POWER WINDOW calibration added in FINAL_FLASHING_API station5. Took a trails on vehicle level found issue in power window now corrected binary and sent to mahindra |
7.00 | |
| 15 | 2025-09-25 21:09 | Pranav Chandrakant Jagajampi | VAT Database | Services added in module HPC_V and FRONT_ZONE |
2.00 | |
| 16 | 2025-09-24 19:57 | Pranav Chandrakant Jagajampi | VAT Database | 1. I checked the logs. In the MCM config state machine, security fails on level one. The module is sending 7F 27 7F because the binary threw an “unexpected error”. So, in this binary, I corrected the message to “Security Access failed”.2. Took trail on vehicle level working fine |
9.00 | |
| 17 | 2025-09-24 19:57 | Pranav Chandrakant Jagajampi | VAT Database | 1. At the end of UB 2 flashing, it is reflecting an error message stating – UNRECOGNIZED_CODE. 2. Checked logs and corrected the station option type from UB_TWO_FLASHING_API station and generated binary3. Took trail on vehicle level working fine |
9.00 | |
| 18 | 2025-09-19 21:12 | Pranav Chandrakant Jagajampi | Analysis | 1. Logs analysis done regarding W616 trails |
5.00 | |
| 19 | 2025-09-18 20:39 | Pranav Chandrakant Jagajampi | Testing | 1. With new binary trails, took on AX7L vehicle and ran all stations.2. Logs checked, working fine |
9.00 | |
| 20 | 2025-09-17 18:04 | Pranav Chandrakant Jagajampi | VAT Database | ESCL start comm and configuration kept in the offline station and removed from the final line station. Created IMMO module configuration test and mapped it in the OFFLINE_FLASHING_API station. In the broadcast decode option, types are optimized for W616. |
5.00 | |
| 21 | 2025-09-16 18:49 | Pranav Chandrakant Jagajampi | Inter-team Meetings | 1. Multifile flashing message sent to Tushar2. Regarding the IPMB issue message sent to Bill. |
1.00 | |
| 22 | 2025-09-15 21:29 | Pranav Chandrakant Jagajampi | VAT Database | 1. Option type updated for W6162. BEV HPC_C services updated in database |
9.00 | |
| 23 | 2025-09-09 21:16 | Pranav Chandrakant Jagajampi | VAT Database | 1. updated services order and removed ITPMS.2. Services name updated in the W616 database |
2.00 | |
| 24 | 2025-08-22 18:09 | Pranav Chandrakant Jagajampi | VAT Database | 1. ESCL not applicable model code added in W616 database2. EPS not applicable model added in Z1 database3. Log analysed for W601 configuration. |
9.00 | |
| 25 | 2025-08-21 20:57 | Pranav Chandrakant Jagajampi | VAT Database | 1. OPtion type updated in W616 database |
5.00 | |
| 26 | 2025-08-20 18:57 | Pranav Chandrakant Jagajampi | VAT Database | 1. Trails and errors were done for the VIN compare feature added in EMS. Working fine on the Ax9L model. |
7.00 | |
| 27 | 2025-08-19 20:28 | Pranav Chandrakant Jagajampi | Project Documentation | ATP signoff sheet updated for W616 |
1.00 | |
| 28 | 2025-08-19 20:27 | Pranav Chandrakant Jagajampi | VAT Database | VIN compare test created for VCU and EMS integrated took a trails on vehicle level found bug corrected in BEV database trails are pending. |
5.00 | |
| 29 | 2025-08-14 19:04 | Pranav Chandrakant Jagajampi | Testing | 1. W601 With all station testing done with latest binary2. W616 With all station testing done with latest binary |
9.00 | |
| 30 | 2025-08-13 19:17 | Pranav Chandrakant Jagajampi | VAT Database | 1. EMS station and option type reviewed2. OFFLINE_FLASHING_API station, station option mod condition updated, test option mod condition updated and option type reviewed.3. CCM removed from FINAL_FLASHING_API.4. ICU added in OFFLINE_FLASHING_API station and removed from FINAL_FLASHING_API station. |
9.00 | |
| 31 | 2025-08-12 20:08 | Pranav Chandrakant Jagajampi | VAT Database | 1. PBF logs and remote server analysed for delay to show in the report logic server.2. Cockpit + JIG ECU FLASHING HPC_C/CDC/IS All EOL parametrization HPC-V/MGM/FZ+ Calibration file & All EOL parametrization ESCL All EOL parametrization DATC /ETC/CCM All EOL parametrization MCM All EOL parametrization Test added in UB_TWO and OFFLINE_FLASHING_API station. Condition added, station option modified.3. Vehicle level testing done |
9.00 | |
| 32 | 2025-08-11 20:35 | Pranav Chandrakant Jagajampi | Testing | 1. AX7 L vehicle level testing done. |
2.00 | |
| 33 | 2025-08-11 20:34 | Pranav Chandrakant Jagajampi | VAT Database | The MBFM module differentiated, condition-wise handled, and service names changed. EMS module nomenclature updated to PCM for flashing, configuration, scan IQA, scan EVGT test, write/read IQA test, write EVGT test and services updated. HPC_C variant code service updated ESP module nomenclature updated to ABS for configuration test, and services are updated.EMS flashing progress bar corrected.IQA & EVGT error corrected. |
8.00 | |
| 34 | 2025-08-08 18:05 | Pranav Chandrakant Jagajampi | VAT Database | MBFM module name has been updated.Station option mod updated.Test option mod updated. |
7.00 | |
| 35 | 2025-08-07 19:36 | Pranav Chandrakant Jagajampi | VAT Database | The MBFM module was added in the VAT database for W616 and updated services, condition and test. |
9.00 | |
| 36 | 2025-08-07 19:35 | Pranav Chandrakant Jagajampi | VAT Database | W616 project all ABS test state machine, nomenclature updated. |
9.00 | |
| 37 | 2025-08-07 19:35 | Pranav Chandrakant Jagajampi | VAT Database | Nomenclature updated for all EMS tests. |
9.00 | |
| 38 | 2025-08-01 20:07 | Pranav Chandrakant Jagajampi | Testing | 1. With new runtime 2.0.248.0 took a trail on ZIG level for EMS with VCI config class 21-21-21, and its look working fine2. AX9L vehicle trails done working fine binary3. W601 model flashed with new database working fine |
9.00 | |
| 39 | 2025-08-01 20:05 | Pranav Chandrakant Jagajampi | VAT Database | 1. Unwanted FRONT_ZONE services removed from the database2. All CDC services corrected3. MCM disabled from FINAL_FLASHING_API station4. Connect cable test disabled from W601 and KUV project |
5.00 | |
| 40 | 2025-08-01 20:00 | Pranav Chandrakant Jagajampi | Project Documentation | ATP sign-off sheet prepared for W616.Logs analysed |
4.00 | |
| 41 | 2025-07-30 20:03 | Pranav Chandrakant Jagajampi | Project Documentation | 1. ATP sign-off sheet updated2. All W616 logs analysed |
7.00 | |
| 42 | 2025-07-30 20:02 | Pranav Chandrakant Jagajampi | VAT Database | FRONT_ZONE unwanted services clean up |
1.00 | |
| 43 | 2025-07-29 18:50 | Pranav Chandrakant Jagajampi | VAT Database | 1. VAT tracker updated2. DL3 repair Excel sheet updated3. ATP sign-off sheet updated. |
9.00 | |
| 44 | 2025-07-28 20:53 | Pranav Chandrakant Jagajampi | Testing | With the MAHINDRA_5.7.1.70 binary, MAHINDRA_5.6.41.96.3, and MAHINDRA_5.7.1.71 trails took on AX9L AT Gasoline vehicle. |
3.00 | |
| 45 | 2025-07-28 20:52 | Pranav Chandrakant Jagajampi | VAT Database | All parameterization for WLC_Front to be moved from offline station to final line station. - Done All parameterization for front zone to be removed from final line station, to be executed in offline station only. - Done All parameterization for HPCC to be moved from final line station to offline station. - Done All parameterization for MCM to be moved from final line station to offline station. - Done A new separate state machine and test were added for MCM_BOOTSTRAP_TRIGGER and MCM_BOOTSTRAP_STATUS in the MCM module to the UB_TWO_FLASHING_API station. – New discussed points added A new separate state machine and test were added for CDC_AX_MCM_BOOTSTRAP_TRIGGER and CDC_AX_MCM_BOOTSTRAP_STATUS in the MCM module to the UB_TWO_FLASHING_API station. FRONT_ZONE_REMOTE_START_CONFIGURATION write and read services added to the database.WLC_CONFIG_STATION is already present in the database. So, I disabled the WLC_START_COMM, WLC_CONFIG and WLC_CLEAR_CODE test and added a new FRONT_ZONE config test.In WLC_CONFIG_STATION, I added FETCH_WEB_API test -> HPC_V routing test -> HPC_V Start COMM test -> FRONT_ZONE start comm test -> FRONT_ZONE_REMOTE_CONFIG test (FRONT_ZONE_REMOTE_START_CONFIGURATION service added for write and read)-> FRONT_ZONE clear code test. – New discussed points addedFRONT_ZONE calibration flashing disabled from OFFLINE_FLASHING_API and FINAL_FLASHING_API,The CDC module message appeared at the OFFLINE_FLASHING_API station, which I disabled from OFFLINE_FLASHING_API.IMMO not applicable model removed from Z1. |
9.00 | |
| 46 | 2025-07-25 20:42 | Pranav Chandrakant Jagajampi | Testing | 1. On AX 9L with FINAL_FLASHING_API and OFFLINE_FLASHING_API taking trails2. On AX 5 with FINAL_FLASHING_API, UB_TWO_FLASHING_API and OFFLINE_FLASHING_API taking trails |
4.00 | |
| 47 | 2025-07-25 20:41 | Pranav Chandrakant Jagajampi | VAT Database | I checked the logs, and below points are updated in the database, FRONT_ZONE missing services added FRONT_ZONE unwanted services updated from the API side OFFLINE_FLASHING_API station, I updated FRONT_ZONE_ROUTING flashing test. HPC_C service cross-checked HEX file mapping done with the help of Sagar AX9L -> i. FRONT_ZONE -> Cal flash on OFFLINE_FLASHING_API AX5 -> i. FRONT_ZONE_PLUS -> Routing flashing on OFFLINE_FLASHING_API ii. FRONT_ZONE_VTA -> Cal flashing on UB_TWO_FLASHING_API AX3 -> i. MBFM Cal flash disabled -> OFFLINE_FLASHING_API station and FINAL_FLASHING_API station MX -> i. MBFM, FRONT_ZONE and FRONT_ZONE_PLUS disabled in all stations |
5.00 | |
| 48 | 2025-07-24 21:09 | Pranav Chandrakant Jagajampi | Testing | 1. With AX5 and AX9L vehicle testing done |
4.00 | |
| 49 | 2025-07-24 21:08 | Pranav Chandrakant Jagajampi | VAT Database | For report will visible for Reprot logic, broadcast decode updatedHPC_C services name renamed now HPC_C all services will work. HPC_C and CDC module added in OFFLINE_FLASHING_API and condition-wise managed. In OFFLINE_FLASHING_API -> MX vehicle MBFM, FZ not present, condition added. AX3 vehicle MBFM Cal file & parameterisation added. AX5 vehicle FZ Routing file & parameterisation added. AX7 onward vehicle FZ Cal file & parameterisation added. In UB_TWO_FLASHING_API -> AX5 vehicle Cal file added. |
6.00 | |
| 50 | 2025-07-24 21:06 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | 1. MRV DL3 is configured for W616 |
9.00 | |
| 51 | 2025-07-22 18:29 | Pranav Chandrakant Jagajampi | Analysis | 1. Analyse why data is not going to report Logiq.2. Remotely from server checked partial logs, wrapper class.3. Found an issue that needs to be added in VAT. |
6.00 | |
| 52 | 2025-07-17 21:38 | Pranav Chandrakant Jagajampi | Testing | - AX5 vehicle trail took with all station like EMS flashing, Offline flashing, UB_Two flashing and final flashing station |
2.00 | |
| 53 | 2025-07-17 21:37 | Pranav Chandrakant Jagajampi | VAT Database | - For W616 new model code was added in the broadcast decode- FRONT_ZONE station option mod corrected in UB_TWO_FLASHING station- FRONT_ZONE parameterisation added in UB_TWO_FLASHING_STATION- AT and MT conditions updated in FINAL and REPAIR stations- AMP not present condition updated in broadcast decode- Z1 new model code added in smartcore added |
7.00 | |
| 54 | 2025-07-16 21:12 | Pranav Chandrakant Jagajampi | Testing | MX5 vehicle testing done in S block |
5.00 | |
| 55 | 2025-07-16 21:12 | Pranav Chandrakant Jagajampi | VAT Database | 1. FRONT_ZONE_VAT new module created.2. Station option mods set.3. Flashing state machine created.4. EXCEL file imported.5. EPS SAS calibration added in FL station for W616.6. Config test set in UB_TWO_FLASHING_API station |
4.00 | |
| 56 | 2025-07-15 21:55 | Pranav Chandrakant Jagajampi | Testing | 1. AX7L above vehicles trails done with binary version 5.7.1.622. AX5 vehicle trails done with binary version 5.7.1.623. In all 11 DL3s, the binary was updated, the configuration file was updated, and the HEX file was updated. |
6.00 | |
| 57 | 2025-07-14 18:15 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | Gate pass renewal done |
1.00 | |
| 58 | 2025-07-14 18:13 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | Simulation setup done |
4.00 | |
| 59 | 2025-07-11 18:07 | Pranav Chandrakant Jagajampi | VAT Database | 1. New latest W616 VAT binary generated and sent to MAHINDRA for testing purpose. |
1.00 | |
| 60 | 2025-07-10 20:54 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | 1. Five DL3 i are configured for S block. New runtime, firmware, binary and required setup.2. Tested and working fine. |
10.00 | |
| 61 | 2025-07-09 19:25 | Pranav Chandrakant Jagajampi | Analysis | HPC_AD log analysed and sent mail to MAHINDRA |
2.00 | |
| 62 | 2025-07-08 21:38 | Pranav Chandrakant Jagajampi | VAT Database | 1. Simulation-related ticket raised to the IT team2. A clear code test was created for W616 |
9.00 | |
| 63 | 2025-07-08 21:37 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | DL3 configuration for S block |
9.00 | |
| 64 | 2025-07-03 19:18 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | W616 Simulation setup done on my laptop with the help of the IT team. |
9.00 | |
| 65 | 2025-07-03 19:17 | Pranav Chandrakant Jagajampi | Analysis | 1. Simulation setup-related things info collected from IT team. Due to lack of admin rights work is in progress. 2. Clear code test created for HPC_V and MGM |
9.00 | |
| 66 | 2025-07-01 17:24 | Pranav Chandrakant Jagajampi | Analysis | Error messages in UI checked and analysed. |
9.00 | |
| 67 | 2025-07-01 17:23 | Pranav Chandrakant Jagajampi | VAT Database | All service configurations are based on applicability. Front zone and front zone plus files flashing in the 3 out of 4 AX5 variants.UB_WTO_FLASHING_API station created. |
4.00 | |
| 68 | 2025-06-26 20:27 | Pranav Chandrakant Jagajampi | VAT Database | 1. GASOLINE vehicle EMS security condition corrected.2. New services added in the VAT database for W6163. REPAIR_FLASHING_API station created and removed unwanted tests from the database. |
4.00 | |
| 69 | 2025-06-26 20:26 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | Supported Aadhav to install the BEV configuration in MRV DL3 remotely. Testing and trials done. |
2.00 | |
| 70 | 2025-06-25 21:17 | Pranav Chandrakant Jagajampi | Testing | 1. FRONT_ZONE CANALYSER log taken on main OBD with VCICONFIG class 21-21-212. LOG analysed FB updated3. FRONT_ZONE flashing on CANFD trails took on vehicle level, but due to the model code wrong test sequence not executed4. New services added in W616 modules5. EMS on gasoline trails took on ZIG level with the W616 database. |
9.00 | |
| 71 | 2025-06-24 18:43 | Pranav Chandrakant Jagajampi | Analysis | 1. CANFD on FRONT ZONE log analysed.2. Yesterday, 3 logs were analysed with the MAIN OBD and 24-pole connector, Only the main OBD connector.3. FB was updated and assigned to Alex and Dustin. |
9.00 | |
| 72 | 2025-06-23 21:26 | Pranav Chandrakant Jagajampi | Testing | 1. FRONT_ZONE on CANFD and all modules on CAN took 3 different different trails with collected CANLYSER logs. |
2.00 | |
| 73 | 2025-06-23 21:25 | Pranav Chandrakant Jagajampi | VAT Database | HPC_V_A53 routine, config state machine and services added Z1 new model code added Gasoline flashing procedure added, condition given to the EMS test IQA and EVGT nomenclature changed PCM to EMS in each set of fault states in the state machine |
7.00 | |
| 74 | 2025-06-23 21:24 | Pranav Chandrakant Jagajampi | Testing | 1. FRONT_ZONE on CAN took a trails on vehicle2. FRONT_ZONE on CANFD took a trails on vehicle3. FRONT_ZONE GW flashing took a trail on vehicle4. FRONT_ZONE CALIBRATION flashing took a trail on a vehicle5. FRONT_ZONE on CANFD and downstream ECU on CAN took a trail on vehicle level |
8.00 | |
| 75 | 2025-06-23 21:22 | Pranav Chandrakant Jagajampi | VAT Database | In this binary FRONT_ZONE flashing erase routine, corrected. |
1.00 | |
| 76 | 2025-06-19 22:25 | Pranav Chandrakant Jagajampi | Testing | 1. FRONT_ZONE flashing trail took on vehicle2. FRONT_ZONE on CAN trails took on vehicle3. FRONT_ZONE on canfd took trails on vehicle. |
5.00 | |
| 77 | 2025-06-19 22:23 | Pranav Chandrakant Jagajampi | VAT Database | 1. FRONT_ZONE module converted on CAN.2. FRONT_ZONE module converted on CANFD3. All modules converted on CANFD4. FLASHING TEST enabled |
4.00 | |
| 78 | 2025-06-17 20:28 | Pranav Chandrakant Jagajampi | Testing | 1. With the CANFD GW vehicle, EMS flashing trails are taken. Working fine on both scenarios, W601 and W616. |
2.00 | |
| 79 | 2025-06-17 20:26 | Pranav Chandrakant Jagajampi | VAT Database | 1. EMS ECU selection automatically differentiates with W601 and W616 done.2. Floating logo state machine and broadcast decode updated in W616 database. |
4.00 | |
| 80 | 2025-06-17 20:25 | Pranav Chandrakant Jagajampi | VAT Database | 1. FRONT_ZONE canfd found an issue in EMS ECU flashing.2. Corrected and temporarily given to Mahindra. |
3.00 | |
| 81 | 2025-06-16 21:31 | Pranav Chandrakant Jagajampi | VAT Database | 1. SYN retry time and SYN waiting time updated.2. WLC_REAR test are updated from OFFLINE_FLASHING_API station3. 5 DL3 checked keep or domain or not |
4.00 | |
| 82 | 2025-06-13 21:45 | Pranav Chandrakant Jagajampi | VAT Database | 1. HPC_C services addition2. MCM services addition3. ICU services addition4. Option type updated for HPC_C, MCM and ICU5. WLC_FRONT and WLC_REAR option type addition6. Module name analysed for all modules |
9.00 | |
| 83 | 2025-06-12 21:03 | Pranav Chandrakant Jagajampi | VAT Database | 1. WLC_FRONT and WLC_REAR name updated in state machine.2. WLC_REAR and WLC_FRON services added new state machine created.3. FRONT_ZONE_PLUS CANFD and FRONT_ZONE_CANFD flashing test checked and updated FRONT_ZONE_PLUS module in init modules.4. VCU test updated in W616 backup testing database, and took trails on vehicle level |
7.00 | |
| 84 | 2025-06-11 19:22 | Pranav Chandrakant Jagajampi | VAT Database | 1. WLC_FRONT and WLC_REAR services renamed, module name renamed. |
3.00 | |
| 85 | 2025-06-10 18:05 | Pranav Chandrakant Jagajampi | VAT Database | 1. New station created for W616 routine run2. FRONT_ZONE, SRS and EPS calibration added in routine station3. WLC_1 and WLC_2 module name changed to WLC_Front and WLC_Rear4. Services updated in WLC_Front and WLC_Rear5. ICU module added6. MCM module added7. HPCC module added8. Station option mod updated9. Broadcast decode option type updated10. FINAL_FLASHING_API and OFFLINE_FLASHING_API station updated. |
9.00 | |
| 86 | 2025-06-09 18:09 | Pranav Chandrakant Jagajampi | VAT Database | 1. FRONT_ZONE flashing state machine created.2. EXCEL import in database for FRONT_ZONE.3. test_option_mods updated.4. FRONT_ZONE_PLUS flashing state machine created.5. EXCEL import in database for FRONT_ZONE_PLUS6. TEST OPTION mods updated7. Config items added in doc sheet. updated and share to tushar. |
5.00 | |
| 87 | 2025-06-06 18:35 | Pranav Chandrakant Jagajampi | Testing | 1. MGM flashing disabled from W601 Repair flashing station and took a trail on vehicle level.2. Same FRONT_ZONE_PLUS flashing we done in OFFLINE station and disabled in FINAL_STATION |
3.00 | |
| 88 | 2025-06-06 18:33 | Pranav Chandrakant Jagajampi | VAT Database | 1. FRONT_ZONE flashing procedure log analysed and flash procedure implemented in database.2. FRONT_ZONE_PLUS flashing procedure log analysed and flash procedure implemented in database |
6.00 | |
| 89 | 2025-06-05 19:50 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | DL3 000102, DL3 000109, DL3 000108 Configured today.Binary file, Firmware updated, New runtime installed, station file updated, VCIConfig file updated, configuration file updated.DL3 003032 and 000101 binary, station file, firmware and runtime updated. |
9.00 | |
| 90 | 2025-06-04 21:22 | Pranav Chandrakant Jagajampi | VAT Database | 1. New services added in all module in W616 database2. Z1 option type verification done. FVC unwanted model removed. |
5.00 | |
| 91 | 2025-06-04 21:21 | Pranav Chandrakant Jagajampi | Testing | 1. VCU flashing testing through W616 project database done. |
4.00 | |
| 92 | 2025-06-03 20:19 | Pranav Chandrakant Jagajampi | Testing | VCU implementation in W616 database testing done |
2.00 | |
| 93 | 2025-06-03 20:18 | Pranav Chandrakant Jagajampi | VAT Database | VCU config item added VCU tester present test added VCU flashing test added VCU configuration added Station: TESTING_STATION |
7.00 | |
| 94 | 2025-06-03 08:48 | Pranav Chandrakant Jagajampi | Testing | 1. VCU on CANFD testing done on V-block zig. |
2.00 | |
| 95 | 2025-06-03 08:48 | Pranav Chandrakant Jagajampi | VAT Database | 1. New VCU module added in W616 for trail purposes2. Config item set as CANFD3. New testing station created for CAN_FD testing4. Tester present command added for VCU |
1.00 | |
| 96 | 2025-05-29 18:55 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | MRV 1 DL3 configured from BEV to W616 |
1.00 | |
| 97 | 2025-05-28 19:52 | Pranav Chandrakant Jagajampi | Testing | 1. Station differentiation for W616 and W601 trails done.2. Took trails on W616, W601 and Z101 |
6.00 | |
| 98 | 2025-05-26 20:24 | Pranav Chandrakant Jagajampi | VAT Database | 1. W616 and W601 differentiation state machine updated.2. Trails are pending |
1.00 | |
| 99 | 2025-05-22 21:13 | Pranav Chandrakant Jagajampi | VAT Database | 1. New station created for W6162. New model code addition for W6163. MGM config state machine created and assigned in FINAL_FLASHING_API4. MGM services added5. All module services validated |
7.00 | |
| 100 | 2025-05-21 20:50 | Pranav Chandrakant Jagajampi | VAT Database | 1. New model code addition in W6162. New service addition in W616 |
2.00 | |
| 101 | 2025-05-20 20:54 | Pranav Chandrakant Jagajampi | Testing | 1. IQA EVGT test updated 10 sec. delay added between IQA and EVGT session trail took on MX and Ax7L vehicle2. EMS on doip converted for W616 trail took on AX7L |
6.00 | |
| 102 | 2025-05-20 20:53 | Pranav Chandrakant Jagajampi | VAT Database | 1. IQA EVGT test updated 10 sec. delay added between IQA and EVGT session2. EMS on doip converted for W6163. Z1 new service added |
2.00 | |
| 103 | 2025-05-19 22:02 | Pranav Chandrakant Jagajampi | Testing | 1. MX fresh vehicle IQA EVGT written test done. NRC 37 occurred for EVGT.2. MX already written IQA and EVGT took trails working fine3. DoIP fresh vehicle IQA EVGT written trail done. working fine.4. DoIP already written IQA EVGT took trails working fine. |
8.00 | |
| 104 | 2025-05-16 20:07 | Pranav Chandrakant Jagajampi | VAT Database | 1. IQA state machine analysed,2. IQA state machine updated for Doip3. IQA state machine created for CAN and CANFD4. IQA state machine added in W616_EOL_FLASHING station, as well as a condition added for particular protocol level |
9.00 | |
| 105 | 2025-05-15 19:28 | Pranav Chandrakant Jagajampi | Testing | 1. IQA test analysed2. IQA test updated 3. IQA trails done on vehicle |
9.00 | |
| 106 | 2025-05-14 19:17 | Pranav Chandrakant Jagajampi | Testing | 1. IQA and EVGT logs analysed2. IQA and EVGT test corrected3. IQA and EVGT trails done. EVGT is pass properly but IQA have NRC issue |
9.00 | |
| 107 | 2025-05-13 20:29 | Pranav Chandrakant Jagajampi | Testing | 1. FLOATING LOGO TRA file checked2. IQA EVGT test updated3. Run on MX vehicle 4. IQA EVGT data not written need to analyse why data not written in module |
7.00 | |
| 108 | 2025-05-08 19:14 | Pranav Chandrakant Jagajampi | Analysis | Cockpit level and final line logs collected to check state machine directions. |
4.00 | |
| 109 | 2025-04-28 20:12 | Pranav Chandrakant Jagajampi | VAT Database | W616 runtime state machine updated for W601 and W616 differentiation |
3.00 | |
| 110 | 2025-04-25 20:44 | Pranav Chandrakant Jagajampi | Project Documentation | 1. ECU wise summery created in excel.2. TEST run summery created in EXCEL3. MAil sent to Abhishek |
3.00 | |
| 111 | 2025-04-21 20:42 | Pranav Chandrakant Jagajampi | VAT Database | 1. W616 and W601 differentiation point discussed and find out solutions2. W616 and W601 log analysis |
5.00 | |
| 112 | 2025-04-10 23:33 | Pranav Chandrakant Jagajampi | Testing | 1. AX7, AX7L - 4 vehicle trails done. |
6.00 | |
| 113 | 2025-04-09 19:37 | Pranav Chandrakant Jagajampi | Team Coordination / Technical Support | DL3 000101 Configured and tested on vehicle |
8.00 | |
| 114 | 2025-04-08 21:21 | Pranav Chandrakant Jagajampi | Testing | 1. W616 on DoIP testing done.2. W616 on CAN testing done. |
5.00 | |
| 115 | 2025-04-08 21:20 | Pranav Chandrakant Jagajampi | VAT Database | After the AMP communication failed, no further test was executed. I corrected the AMP test as well as all modules after the AMP. Now, if AMP does not communicate, then the further tests will execute. The ICC option type was not available because ICC was run in all the variants. With the help of your previous mail, I added the option type in broadcast decode, as well as a condition added for ICC. Now in this binary, it will be working fine. |
2.00 | |
| 116 | 2025-04-07 21:08 | Pranav Chandrakant Jagajampi | Testing | 1. CAN module with updated changes in VAT took a trails on vehicle level.2. DoIP module with updated changes in VAT took a trails on vehicle level. |
3.00 | |
| 117 | 2025-04-04 17:24 | Pranav Chandrakant Jagajampi | VAT Database | 1. New module WLC1, WLC2, ITM, MGM, MID_ZONE added in database.2. TESTER PRESENT, CONFIGURATION, CLEAR CODE test created in database.3. Services added in WLC1, WLC2, ITM, MGM, MID_ZONE.4. Station option mod issue corrected.5. Duplicate module front Zone issue corrected.6. Testing done on MX, MX5 and AX7L vehicle. |
9.00 | |
| 118 | 2025-04-03 19:03 | Pranav Chandrakant Jagajampi | VAT Database | 1. New option type created for W616 project2. EMS security bypass issue cleared3. AMP termination issue solved4. IQA , EVGT test created for scanning5. New test created for HPC_V, HPC_AD, FRM and CRM for configuration. 6. Station option module automated for CAN, CANFD and DoIP.7. The initialization module added for CAN. 8. Services added in HPC_V, HPC_AD, ESP, FRM, CRM. |
8.00 | |
| 119 | 2025-04-02 20:31 | Pranav Chandrakant Jagajampi | VAT Database | I added a gateway present or not present condition. TEST_ON_VEHICLE=Y and N function added When Y is selected at that time, DoIP modules will run When N is selected at that time, CAN modules will run As previously given, the Excel sheet, 19 modules added in the station option mod as DoIP and 9 modules added as a CAN. 10 modules test created for TP, Config and clear code on DoIP as well as CAN. New IQA EVGT write test added. Validation pending, 9 CAN modules are available for testing. Gateway I was assigned as a FRONT_ZONE_PLUS on CAN. IQA and EVGT I added. For parameterization: W616_EOL_FLASHING station useFor EMS flashing and parameterization: W616_EMS_FLASHING station use |
10.00 | |
| 120 | 2025-04-01 20:10 | Pranav Chandrakant Jagajampi | Testing | 1. EMS flashing testing done in W616. There is issue in VCI config files. FB raised. assigned to US |
9.00 | |
| 121 | 2025-03-31 22:39 | Pranav Chandrakant Jagajampi | Testing | W616 EMS flashing trails taken, still success not got. |
9.00 | |
| 122 | 2025-03-31 08:58 | Pranav Chandrakant Jagajampi | Testing | W616_EMS_FLASHING station created. Added EMS flashing and configuration on CAN. Testing done.W616_EOL_FLASHING, I added TCU, HPC_V, HPC_AD, CRM, FRM, FRONT_ZONE on DoIP. Testing done. |
3.00 | |
| 123 | 2025-03-31 08:57 | Pranav Chandrakant Jagajampi | VAT Database | W616_EMS_FLASHING station created. Added EMS flashing and configuration on CAN. W616_EOL_FLASHING, I added TCU, HPC_V, HPC_AD, CRM, FRM, FRONT_ZONE on DoIP.EMS issue corrected. |
6.00 | |
| 124 | 2025-03-27 21:18 | Pranav Chandrakant Jagajampi | Testing | Added 6 modules with Tester Present, Configuration and Clear code: EMS, TCU, ITM, ESP, EPS, and SRS. IQA, EVGT tests are added. EMS Flashing added for Diesel. Test taken on vehicle level. |
2.00 | |
| 125 | 2025-03-27 21:17 | Pranav Chandrakant Jagajampi | VAT Database | Added 6 modules with Tester Present, Configuration and Clear code: EMS, TCU, ITM, ESP, EPS, and SRS. IQA, EVGT tests are added. EMS Flashing added for Diesel. |
8.00 | |
| 126 | 2025-03-26 19:13 | Pranav Chandrakant Jagajampi | VAT Database | 1. W616 new database created in the existing W601 database. |
6.00 | |
| 127 | 2025-03-26 19:12 | Pranav Chandrakant Jagajampi | Testing | 1. OBD cable updated for W616. Ethernet link internal cable bypass to power cable pin16. |
3.00 | |
| 128 | 2025-03-25 08:35 | Pranav Chandrakant Jagajampi | Testing | 1. Existing W6 and Z1 database merge and took trail in DoIP and CANFD protocol |
9.00 | |
| 129 | 2025-03-21 20:59 | Pranav Chandrakant Jagajampi | Testing | 1. With W616 database testing done on Gasoline and Diesel vehicles |
2.00 | |
| 130 | 2025-03-21 20:58 | Pranav Chandrakant Jagajampi | VAT Database | 1. Added initialisation module in EMS, TCU and FRONT_ZONE in database.2. Tester present, configuration and clear code state machine created in database.3. Test and phase created in database for EMS, TCU and FRONT ZONE.4. VCI protocol and data structure added DoIP and CANFD protocol.5. Services added in EMS, TCU and FRONT_ZONE.6. Station option mods updated.7. New station created for W616.8. In broad cast decode updated option types. |
5.00 |